火灾自动报警系统

分享  
VRT-300 VESDAnet Socket
品       牌:
证       书:
价       格:
媒体价            ¥23760.0元
价       格:
建议成交价    
购买方式:
产品热度:
好评
度:
QQ:65890257
类似产品
 VHX-0200 VESDAnet PC...
 VSP-005滤网

详情介绍

属性参数

图片(0)

视频(0)

文章资料

咨询评价

售后保障

年中大促

The VESDAnet™ Interface Card (VN Card) is a simple interface card for the range of Xtralis VESDA VLF smoke detectors. The VN Card provides seamless VESDAnet communication from the detector to other VESDAnet devices, including configuration and monitoring tools.
 

What is VRT-300 VESDAnet ?

VESDAnet is a fault-tolerant proprietary Xtralis VESDA communications protocol. VESDAnet allows the Xtralis VESDA range of smoke detectors, displays, programmers and remote units to communicate with each other on one network.
VRT-300 VESDAnet Socket

 

Why connect to VRT-300 VESDAnet ?

Installing a VESDAnet Interface Card into a VLF detector and connecting to a VESDAnet offers many benefits, including:
Central, convenient communications with Xtralis VESDA detectors 
VESDAnet allows sophisticated configuration, monitoring and control from local or remote sites. So rather than a technician having to connect to each Xtralis VESDA smoke detector individually (sometimes installed high above floor level), they can communicate with all detectors on the network from a central, convenient, location using a laptop.
VESDAnet also allows a system management package (such as Xtralis VSM4) to monitor and report on the status of all devices connected on VESDAnet, facilitating central supervision, management and control of all Xtralis VESDA detectors.
Remote displays and relays for the VLF detector
By installing a VN Card in a VLF detector, remote displays and remote relays can be added to the VLF. This extends the capability and flexibility of the VLF detector.
Features
• Provides seamless VESDAnet fault-tolerant communication
• Quick and simple to install
• Minimal configuration required before operation
• Diagnostic LEDs give visual indication of the card’s status
• Fully transferrable between VLF detectors
Connecting VESDA detectors to building management systems or fire panels
Using an appropriate High Level Interface (HLI), the information on VESDAnet can be transmitted to 3rd party monitoring and control systems such as Building Management Systems (BMS) and Fire Alarm Control Panels (FACP).
Preventing false alarms due to outside air pollution
The VLF can be used as a cost effective reference detector for other active detectors on a VESDAnet. Referencing is a technique used to reduce the risk of unwanted alarms caused by external influences to a building, such as air pollution. It works by offsetting the signal from the active detector in the protected area with a reference signal from a detector monitoring the fresh air intake to the area. This results in the active detector measuring changes in smoke levels that are due only to events in the protected area, rather than those external to the area. 
VRT-300 VESDAnet Socket
Having all Xtralis VESDA smoke detectors on a VESDAnet loop allows you to configure and interrogate each detector from a central location, in this case the Facility Manager’s office.
Specifications
Power Consumption:Consumes less than 1 W from the detector at 24 VDC & 42 mA.
Dimensions:Length x Width x Height
             137 mm (5¼”) x 71 mm (2 13/16”) x 20 mm (13/16”)
             Weight    0.08 kg (0.176 lb)
             Terminals 0.2 - 2.5 mm2 (30-12 AWG)
Operating Conditions:
Tested to 0 to 40°C (32 to 104°F)
Detector Ambient 0 to 40°C (32 to 104°F)
Humidity 5% to 95% (non-condensing)
Compatibility
Individual VLF detectors can be interrogated and configured by Xtralis VSC, through their onboard serial interface. However, it is not possible to access other detectors on VESDAnet through this serial port. 
To configure devices via VESDAnet, an High Level Interface (HLI) must be connected to a VESDAnet socket. This socket is available on VLP, VLS and VLC-505 detectors. 
Alternatively, a remote VESDAnet socket module (VRT-300) provides direct connectivity to an HLI or a hand held programmer. A hand-held programmer or High Level Interface (HLI) module cannot be directly  connected to a VLF detector.

 

关于我们
当宁消防网提供的商品保证正品,并提供正规的增值税发票,货物从发出之日起,质保一年,请放心购买。
关于发票
发票说明:当宁消防网所售商品均可提供正规发票。
发票抬头:发票抬头不能为空,您可在下单时,在“备注”处填写您本人/他人的名字或公司名称,发票一旦开出即不可更改、退换。如因客户原因导致的发票抬头错误,恕不能提供发票重开服务,敬请谅解。
签收提醒
为了您的权益能够得到有效的保障,请您在签售货物时务必对商品的型号、数量和外观等内容进行核对验收,并建议您尽量不要委托他人代为签收,若由他人代为签收商品且在没有配送人员在场的情况下发生的验货行为,则视为您所订购商品及包装无任何问题。
退换货
在保证产品包装保存完好、配件、合格证、发票齐全的前提下,若您的产品出现质量问题,只需提供当时购买的订单号,从产品发出之日起,一年内享受当宁消防免费的售后维修服务(配件除外、运费各半)。
特别提醒:
由于本店所售产品为工业品,一旦售出,概不退换,请购买前确认好型号,如确为产品本身质量问题,自签收之日起,在保证产品包装完好不影响二次销售的情况下,可申请退换货,谢谢您的支持!
自产品发出之日起1年内,如遇产品质量问题,请您联系客服处理,经技术确认后,为您作维修处理(运费各半)。
【注意事项】
1.由于本店发错产品,返回运费由我们承担。
2.当宁所售均为全新品,为保护消费者利益,以下情况视为影响二次销售:
1)物品上出现划痕、裂缝;
2)物品上包装破损或已通电使用;
3)密封产品原包装打开;
4)其他可能影响二次销售的;
3.以下情况不予以办理维修:
1)过保产品(超过保质期的产品);
2)人为损坏;
3)非我店售出产品;
4)经鉴定无法维修;
4.请在里面放置一张纸条,上面写清楚故障描述、订单号、原收件人的姓名、电话、收货地址以及寄回物品清单。

全部评价(5)

    5

    2013-07-31 18:18:21

    匿名用户

    VRT-300 VESDAnet Socket主要作用是用于和pclink相连接最后提供给监控电脑使用。

     匿名用户

    来自电脑端用户

    5

    2013-01-18 05:33:37

    林琳

    VRT-300是组vesdanet网络必须要用到的配件之一,稳定性好!

    管理员:

    您好!感谢你对我们的支持,祝您购物愉快!

     林琳

    来自电脑端用户

    2

    2012-09-19 23:36:29

    qwerty123

    VRT-300VESDAnet Socket有什么优势?

     qwerty123

    来自电脑端用户

    5

    2012-09-17 17:51:15

    susan33

    VRT-300 VESDAnet Socket
    价位可以再优惠点吗?

    管理员:

    你可以和我们的销售人员联系一下,祝你购物愉快!

     susan33

    来自电脑端用户

    5

    2012-02-29 21:06:28

    king8fly

    我不认识英文,VRT-300VESDAnet Socket 干什么用的啊?

     king8fly

    来自电脑端用户

总计 5 个记录,共 1 页。 第一页 上一页 下一页 最末页
产品评价
用户名: 匿名用户
E-mail:
评价等级:
评论内容:
相关搭配
关于我们 | 联系我们 | 品牌中心 | 解决方案 | 公司简介 | 咨询热点 | 网站地图
© 2005-2026 当宁消防网-消防产品之家 版权所有,并保留所有权利。
上海市杨浦区淞沪路333号创智天地广场3期12号楼9楼 Tel: 400-928-6119 E-mail: webmaster@dangning.cn

ICP备案证书号:沪ICP备10211324号-3
rss